Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Periodic schedule occurring every 1 15 minutes, from the external system which will update all incidents that have been updated since the last synchronization. This is conditional on having been previously synchronized.Image Removed

Image Added

  1. Synchronize on change is in the direction of Enterprise Tester to JIRA.  A sychronization of all incidents added or updated in Enterprise Tester since last synchronized will be initiated at the time a change occurs to an incident.  This synchronization only updates JIRA with the changes made in Enterprise Tester. 

Image RemovedImage Added

 

The synchronization frequency can also be configured from the Schedules tab. There are 3 options that can be configured:

  1. Adhoc
  2. Periodic
  3. Daily

Note: For Periodic and Daily you can only synchronize Updated Since Last Synchronization.
If you select Synchronize All from the Scope drop down list when you select the Save button the following message will be displayed.

 Image Added

Type

Scope

Direction

Period

Time

Adhoc

You can choose to only update Update entities since the last synchronization or synchronize all Synchronize All.

Four options:
• To External System (From Enterprise Tester)
• From External System ( To Enterprise Tester)
• Bi-Directional (External System changes will synch first)
• Bi-Directional (Enterprise Tester changes will synch first).

N/A

N/A

On Change

The scope can not be changed — it will only synchronize those incidents which have just been changed in Enterprise Tester.

Only supported in the Enterprise Tester to JIRA direction.

N/A

N/A

Periodic

You can only choose to only update Update entities since the last synchronization or synchronize all.

Four options:
• To External System (From Enterprise Tester)
• From External System (To Enterprise Tester)
• Bi-Directional (External System changes will synch first)
• Bi-Directional (Enterprise Tester changes will synch first).

Specify the synchronization frequency in minutes.

N/A

Daily

You can only choose to only update Update entities since the last synchronization or synchronize all. 

Four options:
• To External System (From Enterprise Tester)
• From External System (To Enterprise Tester)
• Bi-Directional (External System changes will synch first)
• Bi-Directional (Enterprise Tester changes will sync first).

N/A

Specify the time using the (24hr clock) when the synchronization will occur daily.

...